Multiplex ELISA Kit For Human Micronutrient Array (7-plex)
<h2>Product Overview</h2>_x000D_<p>The Multiplex Human Micronutrient Array (7-plex) is a fully quantitative chemiluminescent assay allowing concurrent measurement of biomarkers used in nutritional assessment in serum or heparin plasma samples. Analytes CRP, Ferritin, HRP2, sTfR, and Thyroglobulin (Tg) are sandwich ELISAs while AGP and RBP4 are competitive ELISAs. This product is alternatively known in previous publications as Multiplex Micronutrient Assessment Tool (MMAT).</p><p>A Human Micronutrient Assay kit contains a 96-well plate, with each well featuring the 7-plex along with reagents necessary to perform the test. Our high quality reagents help ensure the accuracy of your results.</p><p>Using just 5 µl of sample per well, up to 80 wells can be tested for all seven markers in the panel in 3.5 hours. Multiplex Arrays provide scientists with an easy-to-use and cost effective means of generating a biomarker profile for each sample.</p> _x000D_<h2>Assay Ranges</h2>_x000D_<table class="w-100 table table-striped"><thead class="bg-grey text-white"><tr><th>Analytes</th><th>Assay Types</th><th>Calibrator Range</th><th>Upper Limit of Quantification (ULOQ)</th><th>Lower Limit of Quantification (LLOQ)</th><th>Limit of Detection</th></tr></thead><tbody><tr><td>AGP</td><td>Competitive</td><td>0.36-0.0005 (g/L)</td><td>0.25 (g/L)</td><td>0.0019 (g/L)</td><td>0.00096 (g/L)</td></tr><tr><td>CRP</td><td>Sandwich</td><td>1-0.0014 (mg/L)</td><td>0.7 (mg/L)</td><td>0.0018 (mg/L)</td><td>0.00089 (mg/L)</td></tr><tr><td>Ferritin</td><td>Sandwich</td><td>23-0.032 (µg/L)</td><td>16.17 (µg/L)</td><td>0.041 (µg/L)</td><td>0.021 (µg/L)</td></tr><tr><td>HRP2</td><td>Sandwich</td><td>1.9-0.0026 (µg/L)</td><td>1.33 (µg/L)</td><td>0.0034 (µg/L)</td><td>0.0017 (µg/L)</td></tr><tr><td>RBP4</td><td>Competitive</td><td>1.01-0.0014 (µmol/L)</td><td>0.71 (µmol/L)</td><td>0.0054 (µmol/L)</td><td>0.0027 (µmol/L)</td></tr><tr><td>sTFR</td><td>Sandwich</td><td>4-0.0055 (mg/L)</td><td>2.8 (mg/L)</td><td>0.0071 (mg/L)</td><td>0.0036 (mg/L)</td></tr><tr><td>Thyroglobulin</td><td>Sandwich</td><td>15.1-0.021 (µg/L)</td><td>10.57 (µg/L)</td><td>0.027 (µg/L)</td><td>0.013 (µg/L)</td></tr></tbody></table>_x000D_<h2>Kit Components</h2>_x000D_<p>Each kit contains a 96-well plate (solid plate), with relevant biomarker panel in each well, and contains all reagents required to perform testing. If you want a strip-well format, please contact us for customization.</p>_x000D_<p>Reagents Include:</p>_x000D_<p>Calibrator: Lyophilized, recombinant antigens in a buffered protein base;Calibrator Additive: Purified ferritin antigen in a buffered protein base;Detection Mix: Liquid, 6 mL/vial of biotinylated antibodies in a buffered protein solution with preservatives;Competitor: Lyophilized, biotinylated competitive antigen;Substrate A: Liquid, 3.5 mL/vial;Substrate B: Liquid, 3.5 mL/vial;Sample Diluent (2X): Liquid, 10 mL/vial of a buffered protein solution with heterophilic antibody and rheumatoid factor blockers and preservatives;Streptavidin HRP (1X): Liquid, 6 mL/vial of streptavidin-conjugated horseradish peroxidase;Wash Buffer (20X): Liquid, 50 mL/vial of a concentrated solution of buffered surfactant;Plate Seals (3): Adhesive strips</p>
1700.00€
Διαθέσιμο
Gentaur
Περιγραφή Προϊόντος
Product Overview
_x000D_The Multiplex Human Micronutrient Array (7-plex) is a fully quantitative chemiluminescent assay allowing concurrent measurement of biomarkers used in nutritional assessment in serum or heparin plasma samples. Analytes CRP, Ferritin, HRP2, sTfR, and Thyroglobulin (Tg) are sandwich ELISAs while AGP and RBP4 are competitive ELISAs. This product is alternatively known in previous publications as Multiplex Micronutrient Assessment Tool (MMAT).
A Human Micronutrient Assay kit contains a 96-well plate, with each well featuring the 7-plex along with reagents necessary to perform the test. Our high quality reagents help ensure the accuracy of your results.
Using just 5 µl of sample per well, up to 80 wells can be tested for all seven markers in the panel in 3.5 hours. Multiplex Arrays provide scientists with an easy-to-use and cost effective means of generating a biomarker profile for each sample.
_x000D_Assay Ranges
_x000D_| Analytes | Assay Types | Calibrator Range | Upper Limit of Quantification (ULOQ) | Lower Limit of Quantification (LLOQ) | Limit of Detection |
|---|---|---|---|---|---|
| AGP | Competitive | 0.36-0.0005 (g/L) | 0.25 (g/L) | 0.0019 (g/L) | 0.00096 (g/L) |
| CRP | Sandwich | 1-0.0014 (mg/L) | 0.7 (mg/L) | 0.0018 (mg/L) | 0.00089 (mg/L) |
| Ferritin | Sandwich | 23-0.032 (µg/L) | 16.17 (µg/L) | 0.041 (µg/L) | 0.021 (µg/L) |
| HRP2 | Sandwich | 1.9-0.0026 (µg/L) | 1.33 (µg/L) | 0.0034 (µg/L) | 0.0017 (µg/L) |
| RBP4 | Competitive | 1.01-0.0014 (µmol/L) | 0.71 (µmol/L) | 0.0054 (µmol/L) | 0.0027 (µmol/L) |
| sTFR | Sandwich | 4-0.0055 (mg/L) | 2.8 (mg/L) | 0.0071 (mg/L) | 0.0036 (mg/L) |
| Thyroglobulin | Sandwich | 15.1-0.021 (µg/L) | 10.57 (µg/L) | 0.027 (µg/L) | 0.013 (µg/L) |
Kit Components
_x000D_Each kit contains a 96-well plate (solid plate), with relevant biomarker panel in each well, and contains all reagents required to perform testing. If you want a strip-well format, please contact us for customization.
_x000D_Reagents Include:
_x000D_Calibrator: Lyophilized, recombinant antigens in a buffered protein base;Calibrator Additive: Purified ferritin antigen in a buffered protein base;Detection Mix: Liquid, 6 mL/vial of biotinylated antibodies in a buffered protein solution with preservatives;Competitor: Lyophilized, biotinylated competitive antigen;Substrate A: Liquid, 3.5 mL/vial;Substrate B: Liquid, 3.5 mL/vial;Sample Diluent (2X): Liquid, 10 mL/vial of a buffered protein solution with heterophilic antibody and rheumatoid factor blockers and preservatives;Streptavidin HRP (1X): Liquid, 6 mL/vial of streptavidin-conjugated horseradish peroxidase;Wash Buffer (20X): Liquid, 50 mL/vial of a concentrated solution of buffered surfactant;Plate Seals (3): Adhesive strips
