Gentaur – Ο αξιόπιστος συνεργάτης σας για ερευνητικά αντιδραστήρια & προϊόντα βιοεπιστημών
Gentaur
📧 [email protected] (+32) 2 265 09 20
3CL Protease (MERS-CoV) Inhibitor Screening Assay Kit thumb 1
Gentaur
Kempische Steenweg 305Hasselt3500Belgium
Κατηγορία: Επιχειρήσεις και βιομηχανίες > Επιστήμη και εργαστήρια
3CL Protease (MERS-CoV) Inhibitor Screening Assay Kit
αστέρια0
|Κωδικός: 78278

The 3CL Protease (MERS-CoV) Inhibitor Screening Assay Kit is designed to measure 3CL Protease activity for screening and profiling applications, in a homogeneous assay with no time-consuming washing steps. A protease inhibitor cocktail is included as a positive control.Assay Principle3CL Protease (MERS-CoV) Assay Kit uses a custom-synthesized peptide which has a fluorescence group quenched by a specific quencher. This peptide works as a substrate for 3CL Protease (MERS-CoV) . After proteolytic cleavage, fluorescence product is formed and detected at λexcitation=485 nm and λemission=528 nm.Need us to run inhibitor screens or profile your compounds against 3CL Protease (MERS-CoV) ? Check out ourProtease Screening ServicesorCoronavirus Services.This product has beencited 2 times.

1315.00

Μέγεθος:
96 rxns.
Διαθέσιμο
Ποσότητα:
Προμηθευτής:

BPS BioscienceGentaur

από Gentaur
Γρήγορη Παράδοση

Αστραπιαία αποστολή, εγγυημένη.

Πληρωμή

Πληρωμή κατά την παραλαβή, με κάρτα στο κατάστημα, ή online.

Εγγύηση

Δεν επιστρέφονται προϊόντα κατάλληλης ποιότητας σύμφωνα με το νόμο προστασίας καταναλωτή.

Συσκευασία

Ασφαλής συσκευασία για την προστασία των προϊόντων κατά τη μεταφορά.

Περιγραφή Προϊόντος
The 3CL Protease (MERS-CoV) Inhibitor Screening Assay Kit is designed to measure 3CL Protease activity for screening and profiling applications, in a homogeneous assay with no time-consuming washing steps. A protease inhibitor cocktail is included as a positive control.Assay Principle3CL Protease (MERS-CoV) Assay Kit uses a custom-synthesized peptide which has a fluorescence group quenched by a specific quencher. This peptide works as a substrate for 3CL Protease (MERS-CoV) . After proteolytic cleavage, fluorescence product is formed and detected at λexcitation=485 nm and λemission=528 nm.Need us to run inhibitor screens or profile your compounds against 3CL Protease (MERS-CoV) ? Check out ourProtease Screening ServicesorCoronavirus Services.This product has beencited 2 times.
Σχετικά προϊόντα
Porcelain Buchner Funnel 200 ml, each
16.80 /Qty
Από Gentaur
0(0k)
Porcelain Buchner Funnel 200 ml, each
Other (indicate in Comments) 5 µmol scale
null /Qty
Από Gentaur
0(0k)
Other (indicate in Comments) 5 µmol scale
10 mm Diameter Solid Titanium Tip
504.00 /Qty
Από Gentaur
0(0k)
10 mm Diameter Solid Titanium Tip
Other (indicate in Comments) 5 µmol scale
null /Qty
Από Gentaur
0(0k)
Other (indicate in Comments) 5 µmol scale
10 mm Diameter Solid Titanium Tip
504.00 /Qty
Από Gentaur
0(0k)
10 mm Diameter Solid Titanium Tip
13 mm Diameter Tapped Titanium Tip
595.00 /Qty
Από Gentaur
0(0k)
13 mm Diameter Tapped Titanium Tip