The PDE7A Assay Kit is designed for identification of PDE7A inhibitors using fluorescence polarization. The assay is based on the binding of a fluorescent nucleotide monophosphate generated by PDE7A to the binding agent. The key to the PDE7A Assay Kit is the specific binding agent. Using this kit, only two simple steps on a microtiter plate are required for PDE7A reactions. First, the fluorescently labeled cAMP is incubated with a sample containing PDE7A for 1 hour. Second, a binding agent is added to the reaction mix to produce a change in fluorescent polarization. The FP signal is measured using a fluorescent microplate readercapable of measuring fluorescence polarization.Need us to run inhibitor screens or profile your compounds against PDE7A? Check out ourPhosphodiesterase Screening Services.This product has beencited 2 times.

405.00

Μέγεθος:
96 rxns.
Διαθέσιμο
Ποσότητα:
Προμηθευτής:

BPS BioscienceGentaur

από Gentaur
Γρήγορη Παράδοση

Αστραπιαία αποστολή, εγγυημένη.

Πληρωμή

Πληρωμή κατά την παραλαβή, με κάρτα στο κατάστημα, ή online.

Εγγύηση

Δεν επιστρέφονται προϊόντα κατάλληλης ποιότητας σύμφωνα με το νόμο προστασίας καταναλωτή.

Συσκευασία

Ασφαλής συσκευασία για την προστασία των προϊόντων κατά τη μεταφορά.

Περιγραφή Προϊόντος
The PDE7A Assay Kit is designed for identification of PDE7A inhibitors using fluorescence polarization. The assay is based on the binding of a fluorescent nucleotide monophosphate generated by PDE7A to the binding agent. The key to the PDE7A Assay Kit is the specific binding agent. Using this kit, only two simple steps on a microtiter plate are required for PDE7A reactions. First, the fluorescently labeled cAMP is incubated with a sample containing PDE7A for 1 hour. Second, a binding agent is added to the reaction mix to produce a change in fluorescent polarization. The FP signal is measured using a fluorescent microplate readercapable of measuring fluorescence polarization.Need us to run inhibitor screens or profile your compounds against PDE7A? Check out ourPhosphodiesterase Screening Services.This product has beencited 2 times.
Σχετικά προϊόντα
Porcelain Buchner Funnel 200 ml, each
16.80 /Qty
Από Gentaur
0(0k)
Porcelain Buchner Funnel 200 ml, each
Other (indicate in Comments) 5 µmol scale
null /Qty
Από Gentaur
0(0k)
Other (indicate in Comments) 5 µmol scale
10 mm Diameter Solid Titanium Tip
504.00 /Qty
Από Gentaur
0(0k)
10 mm Diameter Solid Titanium Tip
Other (indicate in Comments) 5 µmol scale
null /Qty
Από Gentaur
0(0k)
Other (indicate in Comments) 5 µmol scale
10 mm Diameter Solid Titanium Tip
504.00 /Qty
Από Gentaur
0(0k)
10 mm Diameter Solid Titanium Tip
13 mm Diameter Tapped Titanium Tip
595.00 /Qty
Από Gentaur
0(0k)
13 mm Diameter Tapped Titanium Tip